R&S®VHF/UHF Multichannel Receivers

VHF R&S EU45(.)U; UHF R&S ED45(.)U; VHF/UHF R&S ET45(.)U

Options

Designation
Type
Uses, specifications, features and benefits
Options
Control Unit
R&S® GB406
For ground-to-air and naval radiocommunications.
Note: For further information, see Related Links at the bottom of this page
Bus Coupler
R&S® GV400
For the configuration of complex radio systems with several (m) Control Units R&S® GB406 and several (n) radios
Note: For further information, see Related Links at the bottom of this page
Front Options
VHF/UHF Guard Receiver
R&S® ET402
  • Complete independent dual receiver
  • Monitoring of the international distress frequencies in the VHF (121.5 MHz) or UHF range (243 MHz)
  • VHF/UHF switchover
    - manual by front panel switch or
    - automatic depending on the main receiver frequency range
  • Antenna connection
    - via main receiver or
    - via separate Guard RX Antenna Interface R&S® GI417U (option)
  • Special transceiver models (e.g. .27 + .28) allow two R&S® ET402 to be inserted
    in parallel for simultaneous monitoring of the VHF and UHF distress frequencies
  • Sensitivity: =2.5 µV (VHF)/=3 µV (UHF) (m = 0.3; fm = 1 kHz; S + N / N = 10 dB, weighted to ITU-T)
  • Image rejection =80 dB
  • Design 1/16 19" front modules
VHF/UHF Preselector
R&S® FT402
  • Automatically tuned preselector filter, interfaced in front of the receiver RF unit
  • For improvement of reception under critical collocation conditions: this option protects
    especially against strong far-off transmit frequencies. R&S® FT402 does not
    replace high-selectivity filters such as R&S® FD221 for nearby-interference suppression
  • Selectivity: bandwidth =13 (25)% VHF/=16 (29)% UHF at 10 (15) dB
  • Permissible input level without damage 50 V EMF (f =30 MHz)/15 V EMF (f >30 MHz)
  • Insertion loss 3 dB typ. (=4 dB)
  • Tuning time =200 µs
  • Design 1/16 19" front modules
VHF/UHF TX/RX Filter
R&S® FT403TR
  • Combined pre/postselector filters for receive and transmit mode
  • For improvement of reception quality (desensitization, IF and image rejection) under critical co-site conditions
  • For improvement of transmission quality (sideband noise)
  • For reduction of necessary TX-to-RX antenna decoupling for interference-free operation
VHF TX/RX Filter
R&S® FU403TR
  • For fixed-channel or FH mode
  • Automatically tuned, switched and interfaced
  • in front of RX VHF/UHF Unit R&S® FT400 (RX mode) or
  • between synthesizer and power amplifier (TX mode)
UHF TX/RX Filter
R&S® FD403TR
  • Included
  • Logic circuits for frequency data encoding, Go/Nogo status etc
  • 2-pole filters
  • Fast GaAs FET switches
  • Low-noise amplifiers for loss compensation
  • Lowpass filters as lightning protection
  • Selectivity: bandwidth =2.2% at 3 dB and =13.3% at 30 dB
  • Tuning time 10 µs
  • Design 2/16 19" front module
Loudspeaker
R&S® GA400
  • For local operation
  • In combination with handheld Microphone R&S® GA016H1 (transceivers)
Rear Options
Wideband/Frequency Interface
R&S® GI411U
  • Wideband AXX data communication
  • External AGC indication
  • EPM (ECCM) operation
Cipher/LINK 11 Interface
R&S® GI412U
  • Cipher operation with standalone KY-58 cipher unit (operated without HAVE QUICK EPM (ECCM) processor in fixed-channel mode)
  • Cipher operation with other COMSEC devices (TDB)
  • With control facility of plain or cipher text, baseband (NB) or diphase (WB)
  • LINK 11 modem connection
AF/V24 Interface
R&S® GI413U
  • AF line connection (not required for AF in connection with DTMF)
  • PTT via separate or AF phantom line
  • V24/RS-232-C/RS-485 bus control
  • Cipher operation
  • EPM (ECCM) operation
  • AF level control: ALC (automatic level control) amplifier included
  • Separate GUARD RX AF outputs
  • Relay outputs for TEST, CARRIER and/or MAIN RX SQUELCH and
  • SQUELCH of GUARD RX 1 + 2 (recommended for special transceiver type models for two R&S® ET402)
Filter/PA Interface
R&S® GI414U
  • Control of 1 (2) automatically tuned filter(s)
  • Control of 1 (2) Rohde&Schwarz linear power amplifier(s)

  • Note: Model .04 is for 2 filters and amplifiers each
DTMF Interface
R&S® GI416U
  • DTMF (dual tone multiple frequency) code radio control (incl. AF) according to ITU-T recommendation Q 23 for Control Units R&S® GB406C3/H3/S3
  • V.11 (X.27)/RS-422-A (R&S® Series400 F-type) radio control: for Control Units R&S® GB404 or R&S® GB408
  • PTT by 2040 Hz tone via AF line (with tone-operated switch and filters) MAIN/STANDBY switching
  • Customer-specific I/O ports, controlled from a PC or by DTMF, allowing the display of user-definable tests (BIT) via Control Units R&S® GB406C/H/S…
Guard RX Antenna Interface
R&S® GI416U
  • Connection of two additional and separate VHF and UHF guard RX antennas (or of one VHF/UHF Dipole R&S® HK014 via Diplexer R&S® FT224)
  • Additional multipurpose RF socket for special customized applications, e.g. for an external drive unit
  • 3 BNC sockets
AF/Telephone Interface
R&S® GI419U
  • AF line connection
  • TX and RX AF/telephone line protection
  • With 1.5 kV isolated 600 O transformers to protect the radio/operator according to EN4103/BZT guideline
  • With lightning fine protection
  • PTT via phantom circuit
  • Transmitting with 8.33 kHz channel spacing
  • With TX AF filter with 4 switchable upper stop frequencies 2.5/2.7/2.9/3.15 kHz (3.4 kHz in addition as radio standard)
  • Local and remote filter selection
DC/100 W FM Interface R&S® GI420U
  • Models .02 and .03: DC supply of Control Units R&S® GB406C/H/S…
  • Model .03: connection of Power Supply R&S® IZ450 for 100 W FM UHF operation
Parallel Interface R&S® GI421U Parallel control via previous R&S® Series400 N-type interface
  • from Control Unit R&S® GB403
  • from other N-type equipment
LINK 11 Interface R&S® GI422U
  • LINK 11 modem connection if COMSEC is not required
  • LINK 11 squelch signaling

  • Note: R&S® VX411 is not required for this application
Auxiliary Equipment
19" Adapter
R&S® KR400U
For integration of up to two receivers and one Power Supply R&S® IN404U to form a compact RX equipment; 19" rack plug-in (3 HU)
xx = 12: for 1 receiver, xx = 13: for 2 receivers
Power Supply
R&S® IN404U
For AC/DC supply of up to two receivers; 1/8 19" plug-in module
EPM (ECCM) Add-Ons
R&S® GP...
Upgrade of fixed-channel radios to EPM (ECCM)
Separate units for cabled connection to the basic radio unit (transceiver, transmitter or receiver);
different versions are available:
EPM (ECCM) Processor
R&S® GP407H1
For HAVE QUICK; DC operated from radio; 19" 1 HU
EPM (ECCM) Processor
R&S® GP407S1
For R&S® SECOS (secure EPM (ECCM) communication system) and for voice only; AC + DC; 19" 1 HU
Data Preprocessor
R&S® GP603P3
For R&S® SECOS (secure EPM (ECCM) communication system) and for data; DC; W × H × D = 50 mm × 130 mm × 295 mm
Service Kits
R&S® KA400
The kits include a wide variety of special-to-type test devices for workshop maintenance/service, such as extender and test cables, extender cards, test adapters. They all are packed in a handy portable case with individually shaped foam inserts and user information.
Available types:

R&S® KA403U
For all R&S® Series400U transmitters, receivers and transceivers

R&S® KA406
For Control Units R&S® GB406C/H/S…

R&S® KA407
For EPM (ECCM) Processors R&S® GP407H1/S1 and timing systems of R&S® GT400 family
Accessories
Audio Accessories Indispensable for local operation or test of transmitters and transceivers; flexible coil-type cable and mounted NF7 connector; also suitable for Remote Control Units R&S® GB406C/H/S… (standard models)
Handset
R&S® GA013
Handle-integrated PTT button; rugged type
Headset
R&S® GA015
Earphones-microphone combination, with cable-integrated PTT button; standard type
Headset
R&S® GA015L
Earphones-microphone combination, with cable-integrated PTT button; light version
Headset
R&S® GA012
Earphones-microphone combination, with cable-integrated PTT button; rugged type
Microphone
R&S® GA016H1
Dynamic; handheld type with PTT button
Set of Mating Connectors
R&S® XT452UZ
For all R&S® Series 400U radios (transceivers, transmitters and receivers)
xx = 12: standard set, incl. connectors for R&S® GI413/416/430U
xx = 13: extended set with additional connectors for all slots
The sets include RF connectors and are without AC connectors (as AC power cord issupplied with radio equipment)